Scanning UV-Visible Spectrophotometers

Features

✧ With the sample temperature control system, the sample temperature can be controlled between -5℃~200℃;
✧ The light source correction mechanism will enable the instrument to position the light source to the best position during self-test. This function can repair the deviation of the focus position of the light source due to vibration during transportation of the instrument. Users do not need to debug after replacing the light source themselves;
✧ The optical system design and circuit control system design are rigorous, and the selection and selection of components are strictly controlled. This instrument has high standards of accuracy, repeatability, low noise and low stray light;
✧ The open sample chamber can be equipped with optional reflection sample racks, automatic 5-link, 6-link, and 8-link sample cell racks, solid sample racks, constant temperature water baths, and automatic samplers.

Applications:

Photometric measurements;
Quantitative measurement;
Qualitative measurement (wavelength scan);
kinetics analysis;
DNA/protein measurements;
Multi-wavelength measurement.

Parameters:

Model No. D-8D-8SD-8Pro
Slit width 2nm and 4nm optional0.5nm, 1nm, 2nm, 4nm, and 5nm adjustable2nm and 4nm optional
Light system Proportional/quasi dual beamProportional/quasi dual beamProportional/quasi dual beam
Wavelength range190~1100nm
(190-339.9nm UV area;
340-1100nm visible area)
190~1100nm
(190-339.9nm UV area;
340-1100nm visible area)
190~1100nm
(190-339.9nm UV area;
340-1100nm visible area)
Wavelength accuracy±0.3nm±0.3nm±0.3nm
Wavelength repetition rate ±0.2nm±0.2nm±0.2nm
Wavelength resolution  0.1nm0.1nm0.1nm
Photometric range -4~4 ABS-4~4 ABS-4~4 ABS
Photometric accuracy ±0.3%T (0~100%T)±0.3%T (0~100%T)±0.3%T (0~100%T)
Photometric Repeatability ±0.1%T (0~100%T)±0.1%T (0~100%T)±0.1%T (0~100%T)
Stray light ≤0.05%T≤0.05%T≤0.05%T
Baseline straightness±0.002A±0.002A±0.002A
Stability ±0.001A/hr@500nm, 0A±0.001A/hr@500nm, 0A±0.001A/hr@500nm, 0A
Photometric noise±0.001A±0.001A±0.001A
Display  320*240 graphic display LCD screen320*240 graphic display LCD screen10.1-inch colorful LCD screen
Data output Connect to upper-level software output and USB flash drive export dataConnect to upper-level software output and USB flash drive export dataConnect to upper-level software output and USB flash drive export data
PC anti-control softwareOptionalOptionalOptional
Wavelength scanHostHostHost
Outer dimension 550×400×300mm640*520*260mm550×400×300mm
Net weight 20kg24kg20kg
Accuracy level Level 2Level 2Level 2