Skip to content

Electrophoresis Power Supplies

Features

One system · two power supplies · independent control · four outputs.
EPHC 400 dual channel high current electrophoresis power supply is different from other electrophoresis power supplies in the market. It has output interfaces controlled independently at both ends of A and B. It can run two different programs at the same time. One machine is dual-purpose, avoiding the conflict when doing experiments at the same time and improving the utilization rate of the instrument. The output current is up to 3000 mA. The product can meet the needs of small vertical electrophoresis, high-throughput electrophoresis and transfer.

Model No.EPHC 400
Dual channel
High current
EPHC 200
High current
EPDU 400
Dual channel
High current
Basic 400
Dual channel
Basic 200
Output specifications300 V, 3000 mA, 350 W (independent dual channel output)300 V, 3000 mA, 350 W600 V, 3000 mA, 500 W (independent dual channel output)300 V, 600 mA, 120 W (independent dual channel output)300 V, 600 mA, 120 W
Output range (programmable)10~300 V, fully adjustable in 1 V increments10~300 V, fully adjustable in 1 V increments10~600 V, fully adjustable in 1 V increments10~300 V, fully adjustable in 1 V increments10~300 V, fully adjustable in 1 V increments
10~3000 mA, fully adjustable in 1 mA increments10~3000 mA, fully adjustable in 1 mA increments10~3000 mA, fully adjustable in 1 mA increments10~600 mA, fully adjustable in 1 mA increments10~600 mA, fully adjustable in 1 mA increments
1~300 W, fully adjustable in 1 W increments1~350 W, fully adjustable in 1 W increments1~500 W, fully adjustable in 1 W increments1~120 W, fully adjustable in 1 W increments1~120 W, fully adjustable in 1 W increments
Output typeConstant voltage, constant current or constant powerConstant voltage, constant current or constant powerConstant voltage, constant current or constant powerConstant voltage, constant current or constant powerConstant voltage, constant current or constant power
Output terminalA and B two sets of independent dual power output, the output ports can be controlled independently without interfering with each other.Four pairs of parallel outputA and B two sets of independent dual power output, the output ports can be controlled independently without interfering with each other.A and B two sets of independent dual power output, the output ports can be controlled independently without interfering with each other.Four pairs of parallel output
Timer control1 minute ~ 99 hours 59 minutes, fully adjustable1 minute ~ 99 hours 59 minutes, fully adjustable1 minute ~ 99 hours 59 minutes, fully adjustable1 minute ~ 99 hours 59 minutes, fully adjustable1 minute ~ 99 hours 59 minutes, fully adjustable
Pause/Resume functionYesYesYesYesYes
Programmable method5 methods could be stored, each of which contains up to 3 steps.5 methods could be stored, each of which contains up to 3 steps.5 methods could be stored, each of which contains up to 3 steps.5 methods could be stored, each of which contains up to 3 steps.5 methods could be stored, each of which contains up to 3 steps.
Real Time ClockYesYesYesYesYes
Automatic recovery after power failureYesYesYesYesYes
Display480*320 pixels,
LED 3.5” touch screen
480*320 pixels,
LED 3.5” touch screen
480*320 pixels,
LED 3.5” touch screen
480*320 pixels,
LED 3.5” touch screen
480*320 pixels,
LED 3.5” touch screen
Security featuresNo-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failureNo-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failureNo-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failureNo-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failureNo-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failure
Input power110~250 VAC, 50~60 Hz110~250 VAC, 50~60 Hz110~250 VAC, 50~60 Hz110~250 VAC, 50~60 Hz110~250 VAC, 50~60 Hz
Operation conditions0~40℃,0~90% humidity,
non-condensing
0~40℃,0~90% humidity,
non-condensing
0~40℃, 0~90% humidity,
non-condensing
0~40℃,0~90% humidity,
non-condensing
0~40℃,0~90% humidity,
non-condensing
Dimension
(W*D*H)
344*293*85 mm344*293*85 mm344*293*85 mm344*293*85 mm344*293*85 mm
Weight 4.05 kg3.75 kg4.05 kg4.05 kg3.75 kg
electrophoresis set