Features
One system · two power supplies · independent control · four outputs.
EPHC 400 dual channel high current electrophoresis power supply is different from other electrophoresis power supplies in the market. It has output interfaces controlled independently at both ends of A and B. It can run two different programs at the same time. One machine is dual-purpose, avoiding the conflict when doing experiments at the same time and improving the utilization rate of the instrument. The output current is up to 3000 mA. The product can meet the needs of small vertical electrophoresis, high-throughput electrophoresis and transfer.
Model No. | EPHC 400 | EPHC 200 High current | EPDU 400 | Basic 400 | Basic 200 |
Output specifications | 300 V, 3000 mA, 350 W (independent dual channel output) | 300 V, 3000 mA, 350 W | 600 V, 3000 mA, 500 W (independent dual channel output) | 300 V, 600 mA, 120 W (independent dual channel output) | 300 V, 600 mA, 120 W |
Output range (programmable) | 10~300 V, fully adjustable in 1 V increments | 10~300 V, fully adjustable in 1 V increments | 10~600 V, fully adjustable in 1 V increments | 10~300 V, fully adjustable in 1 V increments | 10~300 V, fully adjustable in 1 V increments |
10~3000 mA, fully adjustable in 1 mA increments | 10~3000 mA, fully adjustable in 1 mA increments | 10~3000 mA, fully adjustable in 1 mA increments | 10~600 mA, fully adjustable in 1 mA increments | 10~600 mA, fully adjustable in 1 mA increments | |
1~300 W, fully adjustable in 1 W increments | 1~350 W, fully adjustable in 1 W increments | 1~500 W, fully adjustable in 1 W increments | 1~120 W, fully adjustable in 1 W increments | 1~120 W, fully adjustable in 1 W increments | |
Output type | Constant voltage, constant current or constant power | Constant voltage, constant current or constant power | Constant voltage, constant current or constant power | Constant voltage, constant current or constant power | Constant voltage, constant current or constant power |
Output terminal | A and B two sets of independent dual power output, the output ports can be controlled independently without interfering with each other. | Four pairs of parallel output | A and B two sets of independent dual power output, the output ports can be controlled independently without interfering with each other. | A and B two sets of independent dual power output, the output ports can be controlled independently without interfering with each other. | Four pairs of parallel output |
Timer control | 1 minute ~ 99 hours 59 minutes, fully adjustable | 1 minute ~ 99 hours 59 minutes, fully adjustable | 1 minute ~ 99 hours 59 minutes, fully adjustable | 1 minute ~ 99 hours 59 minutes, fully adjustable | 1 minute ~ 99 hours 59 minutes, fully adjustable |
Pause/Resume function | Yes | Yes | Yes | Yes | Yes |
Programmable method | 5 methods could be stored, each of which contains up to 3 steps. | 5 methods could be stored, each of which contains up to 3 steps. | 5 methods could be stored, each of which contains up to 3 steps. | 5 methods could be stored, each of which contains up to 3 steps. | 5 methods could be stored, each of which contains up to 3 steps. |
Real Time Clock | Yes | Yes | Yes | Yes | Yes |
Automatic recovery after power failure | Yes | Yes | Yes | Yes | Yes |
Display | 480*320 pixels, LED 3.5” touch screen | 480*320 pixels, LED 3.5” touch screen | 480*320 pixels, LED 3.5” touch screen | 480*320 pixels, LED 3.5” touch screen | 480*320 pixels, LED 3.5” touch screen |
Security features | No-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failure | No-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failure | No-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failure | No-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failure | No-load detection, load mutation detection, ground leakage detection, overload/short circuit protection, overvoltage detection, input circuit protection, and automatic power on after power failure |
Input power | 110~250 VAC, 50~60 Hz | 110~250 VAC, 50~60 Hz | 110~250 VAC, 50~60 Hz | 110~250 VAC, 50~60 Hz | 110~250 VAC, 50~60 Hz |
Operation conditions | 0~40℃,0~90% humidity, non-condensing | 0~40℃,0~90% humidity, non-condensing | 0~40℃, 0~90% humidity, non-condensing | 0~40℃,0~90% humidity, non-condensing | 0~40℃,0~90% humidity, non-condensing |
Dimension (W*D*H) | 344*293*85 mm | 344*293*85 mm | 344*293*85 mm | 344*293*85 mm | 344*293*85 mm |
Weight | 4.05 kg | 3.75 kg | 4.05 kg | 4.05 kg | 3.75 kg |