Features
✧ The process is fully automatic, one-key to start up, no need special watching;
✧ it can run 4 channels at most simultaneously, each panel can be programmed separately;
✧ samples with different sizes are selectable to save antibody;
✧ precisely control the amount of reagents and operation time to ensure the repeatability of experimental results;
✧ peltier semiconductor refrigeration technology keeps anti-body active, and makes best state of recycling anti-body;
✧ buffer solution will be added after experiment to avoid drying out ;
✧ the interface is user-friendly: 7-inch LCD touch screen, and up to 8 steps could be set in each channel;
✧ the parameters could be set for each step such as operation time, liquid injection volume, repetition times and etc.
Parameters
| Model No. | AB 4800 Automatic Membrane Wash and Incubation Station | ||
| Way to control | |||
| Mechanical control accuracy | High-precision stepper motor | ||
| Operation interface | 7-inch touch screen, easy to set up, with running status visible | ||
| Way of pipetting | With the high-precision automatic detection of liquid level metal Pipette tip | ||
| Function setting | |||
| Antibody recovery | Automatically recover primary and secondary antibodies | ||
| Program steps | Up to 8 experimental steps could be set to meet the whole process of western blotting | ||
| Incubation time per step | Max 99 h | ||
| Auto rinse | Automatic cleaning of pipelines to avoid cross contamination | ||
| Wetting function | When the incubation completed, the buffer is automatically added to the incubation tray to keep the membrane wet | ||
| Channel | |||
| Channel quantity | 4 independent channels without interfering with each other, 4 different running programs could be set .One big incubation tray or a small incubation try for each channel. | ||
| Each channel contains 4 independent reagent tube positions, suitable for 15 ml universal conical bottom centrifuge tubes. | |||
| Sample volume | Big tray: max 15 ml; small tray: max 15 ml | ||
| Sample range | 1.0 – 15 mL | ||
| Incubation tray (L×W×D) | Big tray: 87×71×20 mm, suitable for membrane with big sies; | ||
| Small tray: 87×41×20 mm, suitable for membrane with small sizes to save reagent. | |||
| Shaking way of incubation tray | Left-right | ||
| Shaking speed of incubation tray | 10 gears adjustable. Shaking speed could be selected accordingly. | ||
| Shaking angle of incubation tray | 0 – 13° | ||
| Temperature control | |||
| Cooling way | Semiconductor refrigeration constant temperature control to keep the activity of primary and secondary antibodies. | ||
| Cooling range | 20℃ lower than environment | ||